特征:
手持式,無(wú)需連接電腦無(wú)需連接電源
可直接連接打印機(jī)輸出報(bào)告報(bào)告可導(dǎo)入電腦長(zhǎng)期保存 使用“美標(biāo)檢測(cè)方法”
數(shù)據(jù)精確,可重復(fù)性高一鍵按鈕,使用簡(jiǎn)單 簡(jiǎn)單明了的等級(jí)輸出 詳細(xì)的報(bào)告分析
ISO 等級(jí)識(shí)別
符合國(guó)際工業(yè)標(biāo)準(zhǔn)的追朔體系滿足 GS1 的檢測(cè)要求
軟件更新方便快捷
符合 MIL-STD 130M,ISO-16022, ISO-15415,ISO-15426 ISO-18004 以及 AIQG AS9132 系統(tǒng)
等級(jí)的要求
支持碼制:一維二維條碼通用
Data Matrix, QR CODE,GS1-DataBar(formerly RSS), GS1-Composite Symbology, UPC/EAN, Code 128, Code 39, Code 93, TLC-39, Codabar, PDF 417, Micro PDF 417, Interleaved 2/5 等等
檢測(cè)范圍:51mm
Calibration and traceability
All Webscan systems are calibrated and fully traceable to NIST standards. Calibration is performed by the user in a matter of seconds. You always know that your system is measuring accurately with Webscan technology.
Meets requirements of every industry
GS1 Quality and Data Validation
Verify that your 1D and 2D symbols comply with all GS1 requirements. Print Quality is verified according to ISO 15415 and ISO 15416. Data format failures, which are all-to-common in GS1 bar codes, are clearly spelled out to make corrective action easy.
QR Codes for Marketing and Cell Phone Reading
QR Codes are emerging everywhere. Verify that your QR Codes are constructed and printed correctly in accordance with ISO 18004 and ISO 15415. Webscan verification systems will ensure that your marketing efforts are effective because your QR Codes are in compliance with industry standards for readability.
Healthcare and Pharmaceutical Regulations
These applications are very sensitive to accuracy and dependability.
Verify symbol quality and data format according to GS1 specifications and ISO 15415 to ensure compliant and readable symbols every time!
SPECIFICATIONS |
|
|
|
Ready for the future |
|
||
Symbologies: |
|
|
|
|
The TruCheck Rover verifies linear (1D) and 2D matrix symbols. Be ready to verify |
||
|
|
|
|
Data Matrix, QR Code and Aztec Code symbols now. |
|||
Data Matrix, QR Code, Aztec Code, GS1-DataBar |
|||||||
(formerly RSS), GS1-Composite Symbology, UPC/ |
|
|
|
||||
EAN, Code 128, ITF-14, I25, Code 39, TLC-39, Codabar, |
Compact, hand held -- and other options |
||||||
PDF 417, Micro PDF 417 (limited to Field of View size), |
With its integrated illumination, and compact size and light weight, it is easy to |
||||||
Pharmacode, MSI/Plessey |
|
|
|
||||
|
|
|
move the unit to where it is needed. No cables or cords. The design ensures that |
||||
Field of View Options and X-Dimension Capability |
|||||||
the image is calibrated and in focus when you place the front of the Rover in contact |
|||||||
|
|
|
|
|
|||
Version |
Field of View |
|
|
Min X Dim |
|||
|
|
with the bar code. |
. |
||||
|
|
|
|
|
|||
|
2 “ x 1 1/2” (51 x 38 mm) |
|
8.0 mil |
||||
|
|
|
|
||||
|
|
|
|
|
|||
|
|
|
|
|
Part of a larger Picture |
|
|
Options: |
|
|
|
|
|
CORP |
|
|
|
|
|
Webscan’s broader product line incorporates portable and desktop software |
|||
? Calibration and Conformance Test Cards |
|
||||||
|
enabled hand-held and fixed mount versions . You can import results from the |
||||||
? Wifi Connectivity to User Network |
|
||||||
? Integration with TruCheck Desktop Software |
Rover to the TruCheck desktop software for archival and printing. Choose whichever |
||||||
? Extended Service Plans |
|
|
|
version is right for you, without compromising ease-of-use, or accuracy. |
|||
|
|
|
|
|
|||
Light Source: |
|
|
|
|
|
|
|
? Narrow band 660nm LED |
|
|
|
Webscan commitment |
|
||
Features: |
|
|
|
|
Since 1995, Webscan has been solely focused on designing and manufacturing the |
||
|
|
|
|
|
|
|
|
? CCD Imager with Integrated Illumination |
|
world’s most accurate and reliable bar code verification equipment. We have earned |
|||||
? ISO grading, AIM DPM (45Q only) |
|
the reputation as industry experts from our work on standards committees and |
|||||
? Data export to printer, PDF file |
|
||||||
|
customer support. With Webscan you know your codes are being verified properly |
||||||
? Software easily upgradeable |
|
||||||
|
|
KTOP |
|
|
|||
? Calibrated to NIST traceable standards |
|
and your customers will recognize your commitment to bar code quality. |
|||||
? Parses and validates industry standard |
|
|
|
|
|||
data formats |
|
|
|
|
|
|
|
? Variable aperture size |
|
|
|
|
|
|
|
Decoding/Grading Analysis Specifications: |
|
|
|
|
|||
Full ISO 15415 Grading A, B, C, D, F: Unused Error |
|
|
|
||||
Correction, Modulation, Axial non-uniformity, |
|
|
|
||||
Grid non-uniformity, Symbol Contrast, Reference |
|
|
|
||||
Decode, Finder Pattern Damage, Bar Width Growth (X |
|
|
|
||||
|
T |
|
|
|
|
and Y), Quiet Zone, AIM DPM Grading: Cell Contrast,
Cell Mod.
Physical Characteristics:
? Dimensions (HxWxD) 8.5” x 3.75” x 2.75”
? Weight: 30 oz. (1 lb. 14 oz.)
Environment:
? Temperature: 0-40°C
? Humidity: 5% - 95% noncondensing
Conformance:
? ISO 15416, 15426-1, 15415, 15426-2
? MIL-STD 130 (L through N)
? ISO 16022, 18004, 24778
AIM DPM (only 45Q)
Emaill: foru008@163.com 電話:(020)28219080,28219081,28219082,28219083 傳真:020-28219083 郵編:510663
銷售(馬先生 13829700184 分機(jī):814) 服務(wù)(楊先生 13902293840 分機(jī):805)